All toolsFree calculator
Via aspect-ratio calculator
Enter the board thickness and drill size to see whether a fab can plate the hole reliably.
Via aspect ratio
AR = board thickness ÷ drill
Aspect ratio
Pass5.33 : 1
thickness ÷ drill
Within 8:1, which most fabs plate as standard.
- Smallest drill at 8:1
- 0.2 mm · 7.87 mil
- Smallest drill at 10:1
- 0.16 mm · 6.3 mil
The rule
Plating solution has to flow through the whole hole to deposit copper on the wall. The deeper and narrower the hole, the harder that gets, and the middle of the barrel ends up thin. Fabs therefore limit the ratio of board thickness to drill diameter.
Around 8:1 is standard at most fabs. Many offer 10:1 as an advanced option. Beyond that you need a special process, or blind and buried vias instead.
Formula
AR = board thickness ÷ drill diameter ≤ 8:1 standard ≤ 10:1 advanced > 10:1 ask your fab
Typical values and sources
- 8:1 standard and 10:1 advanced are typical values from fab capability pages, not a standard. Some fabs go higher.
- IPC-2221 and IPC-6012 set the design rules and the minimum copper in the hole that the plating has to reach.
- Use the drill diameter, before plating. A 1.6 mm board with a 0.3 mm drill is about 5.3:1.
Limits differ between fabs. Treat these as starting points and check your fab's capability page.
More calculators
- Stencil area-ratio calculatorAperture size and foil thickness to area ratio, with the 0.66 release guideline.
- Finished-hole calculatorDrill size, plating and tolerance to finished hole size.
- Copper-weight converteroz/ft², µm and mil, with typical finished thickness.
- Panel-utilization calculatorBoard size, spacing and rails to boards per panel and material use.