Skip to content

All toolsFree calculator

Via aspect-ratio calculator

Enter the board thickness and drill size to see whether a fab can plate the hole reliably.

Via aspect ratio

AR = board thickness ÷ drill

mm
mm

Hole diameter before plating.

Board laminateCopper barrel1.6 mm thick · Ø 0.3 mm drill

Aspect ratio

Pass

5.33 : 1

thickness ÷ drill

Within 8:1, which most fabs plate as standard.

Smallest drill at 8:1
0.2 mm · 7.87 mil
Smallest drill at 10:1
0.16 mm · 6.3 mil

The rule

Plating solution has to flow through the whole hole to deposit copper on the wall. The deeper and narrower the hole, the harder that gets, and the middle of the barrel ends up thin. Fabs therefore limit the ratio of board thickness to drill diameter.

Around 8:1 is standard at most fabs. Many offer 10:1 as an advanced option. Beyond that you need a special process, or blind and buried vias instead.

Formula

AR = board thickness ÷ drill diameter

≤ 8:1   standard
≤ 10:1  advanced
> 10:1  ask your fab

Typical values and sources

  • 8:1 standard and 10:1 advanced are typical values from fab capability pages, not a standard. Some fabs go higher.
  • IPC-2221 and IPC-6012 set the design rules and the minimum copper in the hole that the plating has to reach.
  • Use the drill diameter, before plating. A 1.6 mm board with a 0.3 mm drill is about 5.3:1.

Limits differ between fabs. Treat these as starting points and check your fab's capability page.